jagomart
digital resources
picture1_Construction Equipment Pdf 89957 | Iri Em 19 Cabel Splicing   Termination


 133x       Filetype PDF       File size 2.26 MB       Source: www.indresinc.com


File: Construction Equipment Pdf 89957 | Iri Em 19 Cabel Splicing Termination
cable splicing and termination training system equipment maintenance description iri em19 industrial resources inc a training services company this document is the property of industrial resources inc copies and distribution ...

icon picture PDF Filetype PDF | Posted on 15 Sep 2022 | 3 years ago
Partial capture of text on file.
         
         
                    CABLE SPLICING AND TERMINATION 
          TRAINING SYSTEM EQUIPMENT MAINTENANCE DESCRIPTION (IRI-EM19)  
         
         
         
                                    
                                 
                                 
                                 
                                 
                                 
                      INDUSTRIAL RESOURCES, INC. 
                     A TRAINING SERVICES COMPANY 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
        ©This document is the property of Industrial Resources, Inc. Copies and distribution of this document is prohibited 
        unless written authorization is granted by Industrial Resources, Inc. 
                                 
                                 Cable Splicing and Termination 
                                         (IRI-EM19) 
        
        
                        PREFACE 
        
       This Training Equipment Maintenance Description (EMD) has been designed to assist you in 
       meeting the requirements of Module IRI-EM19 of the Electrical Distribution Training Program.  It 
       contains information about the Power Plant, Cable Splicing and Termination.  This includes 
       function, quantity of parts, location of parts, description of the physical construction of the part, and 
       description of the operation of the part, equipment preventive and corrective maintenance, and 
       references.   
        
       You should review each chapter objective.  In doing so you will be better prepared to learn the 
       required information.  You should also inspect the equipment identifying the components and 
       controls.  Should you have additional questions about the equipment, ask your supervisor. 
        
       A separate document, Cable Splicing and Termination Equipment Maintenance Procedure (IRI-
       EM19-EMP), covers detailed maintenance of the Cable Splicing and Termination. 
        
        
        
        
                                            Page 1 
                                                                                      Cable Splicing and Termination 
                                                                                                            (IRI-EM19) 
                  
                                             CABLE SPLICING AND TERMINATION 
                                   TRAINING EQUIPMENT MAINTENANCE DESCRIPTION 
                                                       TABLE OF CONTENTS 
                  
                 1.0     Introduction ......................................................................................................................... 5 
                 1.1     Equipment Function ............................................................................................................ 5 
                 1.2     Equipment Description ....................................................................................................... 5 
                 1.3     Equipment Connections and Interface ................................................................................ 6 
                 2.0     Equipment Major Parts ....................................................................................................... 7 
                 2.1     Cable Splicing and Termination Equipment ....................................................................... 7 
                 2.2     Preparing the Cable for Termination .................................................................................. 9 
                 2.3     Attaching the Cable Lug ................................................................................................... 14 
                 2.4     Cleaning the Cable ............................................................................................................ 15 
                 2.5     Applying Stress Relief Material to the Cable ................................................................... 16 
                 2.6     Positioning and Shrinking the Stress Relief Tube on the Cable ....................................... 16 
                 2.7     Grounding the Cable Shield .............................................................................................. 18 
                 2.8     Applying Sealant to the Cable .......................................................................................... 20 
                 2.9     Placing and Shrinking the HV Tube on the Cable ............................................................ 21 
                 2.10    Completing Outdoor Termination of the Cable ................................................................ 22 
                 3.0     Equipment Preventive and Corrective Maintenance ......................................................... 25 
                 3.1     Cable Splicing and Termination Preventive Maintenance................................................ 25 
                 3.2     Cable Splicing and Termination Corrective Maintenance ................................................ 25 
                 4.0     References .......................................................................... Error! Bookmark not defined. 
                 Appendix 1  - Cable Splicing and Termination Kits..................................................................... 26 
                  
                  
                                                                                                                 Page 2 
                                 Cable Splicing and Termination 
                                         (IRI-EM19) 
        
       List of Figures: 
        Figure 1 – Determining the Required Amount of Insulation Cutback  
        Figure 2 – Insulation Cutback for Cable Shielded with Copper Tape  
        Figure 3 – Installing Ground Braid on Cable Shielded with Copper Tape  
        Figure 4 – Insulation Cutback for Cable Shielded with Wire  
        Figure 5 – Installing the Lug on Wire Shielded Cable  
        Figure 6 – Insulation Cutback for Cable with UniShield  
        Figure 7 – Installing Lug for Cable with UniShield  
        Figure 8 – Insulation Cutback for Cable with Lead Sheath  
        Figure 9 – Soldering the Ground Braid for Cable With Lead Sheath  
        Figure 10 – Positioning the Ground Braid for Cable with Lead Sheath  
        Figure 11 – Applying Red Sealant to Lug Barrel  
        Figure 12 – Installing the Shim Tube  
        Figure 13 – Abrading and Cleaning the Cable  
        Figure 14 – Applying Stress Relief Material to Cable  
        Figure 15 – Positioning and Shrinking Stress Relief Tube  
        Figure 16 – Preparing to Ground Cable with Copper Tape or Lead Sheath  
        Figure 17 – Applying Red Sealant to Cable  
        Figure 18 – Applying More Red Sealant to Cable  
        Figure 19 – Preparing to Ground Wire Shield or UniShield  
        Figure 20 – Cleaning the Jacket for Wire Shield or UniShield  
        Figure 21 – Continue Wrapping Red Sealant for Wire Shield or UniShield  
        Figure 22 – Applying Sealant to Cable at Lug  
        Figure 23 – Applying Sealant to Cable with No Lug 
        Figure 24 – Placing and Shrinking HV Tube on Cable 
        Figure 25 – Trimming the HV Tube on Cable 
        Figure 26 – Positioning Skirt on Cable 
        Figure 27 – Positioning Skirt for Top Feed Termination 
        Figure 28 – Adding Extra Skirts on Cable 
        
                                            Page 3 
The words contained in this file might help you see if this file matches what you are looking for:

...Cable splicing and termination training system equipment maintenance description iri em industrial resources inc a services company this document is the property of copies distribution prohibited unless written authorization granted by preface emd has been designed to assist you in meeting requirements module electrical program it contains information about power plant includes function quantity parts location physical construction part operation preventive corrective references should review each chapter objective doing so will be better prepared learn required also inspect identifying components controls have additional questions ask your supervisor separate procedure emp covers detailed page table contents introduction connections interface major preparing for attaching lug cleaning applying stress relief material positioning shrinking tube on grounding shield sealant placing hv completing outdoor error bookmark not defined appendix kits list figures figure determining amount insula...

no reviews yet
Please Login to review.