jagomart
digital resources
picture1_Soxhlet Extraction Pdf 86700 | 9843777


 233x       Filetype PDF       File size 0.25 MB       Source: www.grosseron.com


File: Soxhlet Extraction Pdf 86700 | 9843777
soxhlet extraction the standard method for the determination heating block units with especially extractors provided with spigots of free fat in foodstuffs is the soxhlet ex exact temperature control for ...

icon picture PDF Filetype PDF | Posted on 14 Sep 2022 | 3 years ago
Partial capture of text on file.
        Soxhlet Extraction
        The standard method for the determination        •  Heating block units with especially        • Extractors provided with spigots 
        of free fat in foodstuffs is the Soxhlet ex-        exact temperature control for                 for draining solvent obviate need to 
        traction.                                           simultaneously processing up to               distill solvent before reuse.
                                                            6 samples.
        behr equipment for the extraction fulfils                                                      • No rotary evaporator is required.
        the most varied requirements of daily            • Extraction systems for four or six 
        laboratory use.                                     samples with linear configuration of    Use of the hydrolysis glassware kit
                                                            individual extrators.                   (for 1, 4 or 6 sample units) enables acid 
           • Extractor sizes from 30 to 250 ml.                                                     digestion to be performed prior to ex-
                                                         • Extractors with a specially developed    traction in accordance with the Weibull 
           • Kompakt units for single sample                siphon tube guarantee uniformity of     and Stoldt method for determination of 
             processing.                                    extraction in all sample positions.     total fat content.
         Kompakt systems for Soxhlet extraction
         804800520 KEX 30                Kompakt-system for 30 ml extraction
         804800522 KEX 100 F             Kompakt-system for 100 ml extraction, w/ spigot
         804800536 KEX 250 F             Kompakt-system for 250 ml extraction, w/ spigot
                                    KEX 30               KEX 100                KEX 250
         Approx. dimensions      71,5 x 23 x 33        71,5 x 23 x 33          80 x 23 x 33
         (H x W x D in cm)
         Weight                      7,5 kg                7,5 kg                 7,5 kg
         Line voltage          230 VAC, 50/60 Hz    230 VAC, 50/60 Hz      230 VAC, 50/60 Hz
         Power rating                450 W                 450 W                  450 W
                                                                                                      KEX 100 F
         Equipment for Soxhlet extraction, 5 sample places
         804850020 DBAS                  DET-basic configuration to be supplemented by
                                         application-specific accessory kits, consisting of a
                                         thermostated aluminum heating block (20 – 300 °C) 
                                         with five 65 mm dia. cavities for sample vessels,
                                         condenser cooling water distributor and
                                         time-temperature controller
         804850023 DE 30                 Accessory kit, for use with the DBAS basic
                                         configuration, providing all required additional
                                         components for the 30 ml Soxhlet extraction
         804850024 DE 100                Accessory kit, for use with the DBAS basic
                                         configuration, providing all required additional
                                         components for the 100 ml Soxhlet extraction
         804850025 DFE 100               Accessory kit, for use with the DBAS basic
                                         configuration, providing all required additional                                  DBAS + DFE 100
                                         components for the 100 ml fat extraction, w/ spigots
        6                                                                                                                                                                                                                                                                                          7
        Equipment for Soxhlet extraction, 6 sample places
        804880020 SMX 30               Workstation for the 30 ml Soxhlet extraction
                                       of six samples, complete
        804880021 SMX 100              Workstation for the 100 ml Soxhlet extraction
                                       of six samples, complete, extractors /w 
                                                                                                                               SMX 100
                                          DBAS + DE/DFE               SMX 30/SMX 100
        Dimensions (H x W x D)        approx. 500 x 1000 x 350 mm  approx. 500 x 1000 x 350 mm
        Weight of complete system            approx. 37 kg                approx. 34 kg
        Line voltage for heating block     230 VAC, 50/60 Hz           230 VAC, 50/60 Hz
        Power rating of heating block          1500 W                       800 W
                                                     Extraction systems with linear sample configuration
                                                     804880031 R 304                Extraction unit with 4 in-line sample positions, 30 ml
                                                     804880032 R 306                Extraction unit with 6 in-line sample positions, 30 ml
                                                     804880022 R 106 S              Extraction unit with 6 in-line sample positions, 100 ml
                                                     804880023 R 104 S              Extraction unit with 4 in-line sample positions, 100 ml
                                                     804880033 R 254 S              Extraction unit with 4 in-line sample positions, 250 ml
                                                     804880034 R 256 S              Extraction unit with 6 in-line sample positions, 250 ml
                                                                                 R 304, R 104 S, R 254        R 306, R 106 S, R 256
                                        R 106 S      Dimensions (W x H x D)        approx. 53 x 74 x 32 cm      approx. 76 x 74 x 32 cm
                                                     (unit w/o glassware)
                                                     Weight                                15,1 kg                      19,8 kg
       behrotest® extraction systems with linear     (unit w/o glassware)
       sample configuration are cost-effective       Rated voltage                                  230 VAC, 50/60 Hz
       and user-friendly solutions for classical     Power                                 1440 W                       2160 W
       Soxhlet and fat extraction requirements:
          • heating at every sample position is 
             individually adjustable
          • a cooling water distributor provides 
             for uniform cooling of all reflux
             condensers
          • convenient built-in stand for storing 
             the reflux condensers between
             extractions
          • holder provided for secure storage 
             of the extractors after removal of 
             the solvent vessel
          • S models: Extractors provided with 
             spigots for draining solvent obviate 
             need to distill solvent before reuse.
6                                                                                                                                      7
The words contained in this file might help you see if this file matches what you are looking for:

...Soxhlet extraction the standard method for determination heating block units with especially extractors provided spigots of free fat in foodstuffs is ex exact temperature control draining solvent obviate need to traction simultaneously processing up distill before reuse samples behr equipment fulfils no rotary evaporator required most varied requirements daily systems four or six laboratory use linear configuration hydrolysis glassware kit individual extrators sample enables acid extractor sizes from ml digestion be performed prior a specially developed accordance weibull kompakt single siphon tube guarantee uniformity and stoldt all positions total content kex system f w spigot approx dimensions x h d cm weight kg line voltage vac hz power rating places dbas det basic supplemented by application specific accessory kits consisting thermostated aluminum c five mm dia cavities vessels condenser cooling water distributor time controller de providing additional components dfe smx workstati...

no reviews yet
Please Login to review.