220x Filetype PDF File size 0.28 MB Source: www.lrb.usace.army.mil
Title Document No. Revision Building Demolition Plan NFSS-0010 REV.0 Building Demolition Plan Niagara Falls Storage Site Building 401 Demolition Lewiston, New York Contract No. W912P4-07-D-0003-0002 Prepared by: TPMC-EnergySolutions Environmental Services, LLC Prepared for the U.S. Army Corps of Engineers, Buffalo District Buffalo, New York AUGUST 2010 TES i AUGUST 2010 W912P4-07-D-0003-0002 REV.0 Title Document No. Revision Building Demolition Plan NFSS-0010 REV.0 Building Demolition Plan Building 401 Demolition Niagara Falls Storage Site Building Demolition Plan Prepared By: 10 AUGUST 2010 Date Reviewed By: 10 AUGUST 2010 , PMP Date Approved By: 10 AUGUST 2010 , PM / CQC System Manager Date X New Plan Title Change Plan Revision Plan Rewrite Effective Date 10 AUG 2010 TES ii AUGUST 2010 W912P4-07-D-0003-0002 REV.0 Title Document No. Revision Building Demolition Plan NFSS-0010 REV.0 CERTIFICATION OF INDEPENDENT TECHNICAL REVIEW COMPLETION OF INDEPENDENT TECHNICAL REVIEW TES, LLC (TES) has DRAFTED the Building Demolition Plan for the Niagara Falls Storage Site Building 401 Demolition Project located in Lewiston, New York. Notice is hereby given that an independent technical review has been conducted that is appropriate to address all regulatory and compliance issues appropriate to the Niagara Falls Storage Site Building 401 demolition, as defined in the TES NFSS Building Demolition Plan. During the independent technical review, compliance with established policy principles and procedures, utilizing justified and valid assumptions, was verified. This included review of assumptions; methods, procedures, and material used in analyses; alternatives evaluated; the appropriateness of data used and level of data obtained; and reasonableness of the results, including whether the product meets the customer’s needs consistent with existing USACE policy. Signature/TES Report Preparer Date 26 JULY 2010 Signature/TES Independent Technical Reviewer Date 26 JULY 2010 Signature/TES Independent Technical Reviewer Date 26 JULY 2010 Signature/TES Independent Technical Reviewer Date 26 JULY 2010 Independent Technical Review Team Members: CERTIFICATION OF INDEPENDENT TECHNICAL REVIEW Significant concerns and the explanation of the resolution are as follows: Item Technical Concerns Possible Impact Resolutions Demolition Plan 1 See attached sheets As noted above, all concerns resulting from independent technical review of the plan have been resolved. Signature/ Date 26 JULY 2010 TES iii AUGUST 2010 W912P4-07-D-0003-0002 REV.0 Title Document No. Revision Building Demolition Plan NFSS-0010 REV.0 TABLE OF CONTENTS 1.0 INTRODUCTION............................................................................................................. 1 1.1 OVERVIEW................................................................................................................... 1 1.2 BACKGROUND.............................................................................................................. 1 2.0 SEQUENCE OF OPERATIONS..................................................................................... 2 2.1 PRE-DEMOLITION ACTIVITIES INCLUDING:.................................................................. 2 2.2 DETAILED DESCRIPTION OF DEMOLITION PROCESS....................................................... 2 2.3 CONTROL MEASURES................................................................................................... 2 2.4 RIGGING AND LIFTING................................................................................................. 3 3.0 SITE MOBILIZATION................................................................................................... 3 3.1 EQUIPMENT.................................................................................................................. 3 3.2 PERSONNEL.................................................................................................................. 4 4.0 PRE-DEMOLITION ACTIVITIES................................................................................ 5 4.1 UTILITY ABANDONMENT............................................................................................. 5 4.2 BUILDING 401 STRUCTURAL INTEGRITY EVALUATION................................................ 5 4.3 HAZARDOUS MATERIALS CHARACTERIZATION........................................................... 6 4.4 PRE-DEMOLITION ACM SURVEY................................................................................. 6 5.0 ASBESTOS ABATEMENT............................................................................................. 7 5.1 TRANSITE..................................................................................................................... 8 5.2 CAULK......................................................................................................................... 8 5.3 GALBESTOS.................................................................................................................. 8 6.0 HAZARDOUS MATERIAL IDENTIFICATION AND REMOVAL.........................9 6.1 ANIMAL MATERIAL NEUTRALIZATION........................................................................ 9 6.2 LEAD BASED PAINT (LBP)........................................................................................ 10 7.0 BUILDING PREPARATIONS...................................................................................... 11 7.1 TRENCH AND DRAIN PLUGGING................................................................................. 11 7.2 RADIOLOGICAL CONTAMINATION ABATEMENT......................................................... 11 7.3 PREMATURE COLLAPSE / COMPETENT PERSON.......................................................... 12 7.4 FIRE SAFETY PROCEDURES / PREVENTION................................................................. 13 7.5 WORK AREA INGRESS/EGRESS.................................................................................. 13 7.6 SEVERE WEATHER STOPPAGE CONSIDERATION......................................................... 13 8.0 DEMOLITION ACTIVITIES....................................................................................... 14 8.1 WATER MANAGEMENT.............................................................................................. 14 8.2 DUST CONTROL METHODS......................................................................................... 15 8.3 STRUCTURE DEMOLITION.......................................................................................... 16 8.3.1 Silo Demolition 16 8.3.2 Building 401 Demolition 16 TES iv AUGUST 2010 W912P4-07-D-0003-0002 REV.0
no reviews yet
Please Login to review.