          CERTIFICATE OF ACCREDITATION 
                  The ANSI National Accreditation Board 
                               Hereby attests that 
                            MadgeTech, Inc. 
                               6 Warner Road 
                              Warner, NH 03278 
                             Fulfills the requirements of 
                          ISO/IEC 17025:2017 
                                 In the field of 
                             CALIBRATION 
         This certificate is valid only when accompanied by a current scope of accreditation document. 
                 The current scope of accreditation can be verified at www.anab.org. 
           
                             
            ______________________________ 
              R. Douglas Leonard Jr., VP, PILR SBU 
              Expiry Date: 28 June 2023                      
               Certificate Number: AC-2481 
                                                                 
             This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017. 
             This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory 
                 quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). 
                                                                                           
                                SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 
                                                                         
                                                            MadgeTech, Inc. 
                                                                6 Warner Road 
                                                              Warner, NH 03278 
                                                   Dianne Moulton            (603) 456-2011 
                                                           dianne@madgetech.com 
                                                                         
                                                            CALIBRATION 
                                                                         
                                     Valid to: June 28, 2023                   Certificate Number: AC-2481 
         Thermodynamic 
          Parameter/Equipment                  Range             Expanded Uncertainty of           Reference Standard, Method, 
                                                                     Measurement (+/-)                    and/or Equipment 
                                                                                                   Fluke 5616 PRT with Fluke 1502A 
                                             (-84 to 5) °C                  0.039 °C                Indicator, Fluke 7381 Deep-Well 
                                                                                                           Bath with Methanol 
                                                                                                   Fluke 5616 PRT with Fluke 1502A 
                                                                                   
                                             (5 to 80) °C                   0.039°C                 Indicator, Fluke 7321 Deep-Well 
                                                                                                       Bath with Distilled  Water 
                                                                                                   Fluke 5616 PRT with Fluke 1502A 
                                                                                   
                                            (80 to 140) °C                  0.036°C                 Indicator, Fluke 7321 Deep-Well 
                                                                                                         Bath with Silicone Oil 
                                                                                                    Direct Comparison using Vaisala 
                                            (10 to 24) °C                   0.49 °C                 HMP155 Temperature/ Humidity 
          Temperature – Measuring                                                                 Probe and Indicator, Environmental 
                  Equipment                                                                                     Chamber 
                                                                                                    Direct Comparison using Vaisala 
                                            (24 to 26) °C                   0.32 °C                 HMP155 Temperature/ Humidity 
                                                                                                  Probe and Indicator, Environmental 
                                                                                                                Chamber 
                                                                                                    Direct Comparison using Vaisala 
                                            (26 to 50) °C                   0.87 °C                 HMP155 Temperature/ Humidity 
                                                                                                  Probe and Indicator, Environmental 
                                                                                                                Chamber 
                                                                                                    Direct Comparison using Vaisala 
                                            (50 to 60) °C                    1.1 °C                 HMP155 Temperature/ Humidity 
                                                                                                  Probe and Indicator, Environmental 
                                                                                                                Chamber 
         Version 011  Issued: April 07, 2022                     www.anab.org 
                                                                                                                                         
                                                                    Page 1 of 2 
                                                                       
       Thermodynamic 
        Parameter/Equipment          Range         Expanded Uncertainty of   Reference Standard, Method, 
                                                      Measurement (+/-)           and/or Equipment 
                                                                             Fluke 5616 PRT with Fluke 1502A 
        Temperature – Measuring   (50 to 420) °C           0.14 °C            Indicator, Fluke 9173 Metrology 
              Equipment                                                                  Bath 
                                     -196 °C               0.059 °C          LN2 Dewar, Fluke 5616 PRT with 
                                                                                  Fluke 1502A Indicator 
                                                                              Direct Comparison using Vaisala 
           Relative Humidity      (10 to 90) %RH           1.4 %RH            HMP 155 Temperature/Humidity 
                                                                                   Probe and Indicator 
        
       Mass and Mass Related 
        Parameter/Equipment          Range         Expanded Uncertainty of   Reference Standard, Method, 
                                                      Measurement (+/-)           and/or Equipment 
                                  (0 to 500) psig          0.084 psi             Direct comparison using  
                                  (1 to 500) psia          0.093 psi              Mensor CPC6000 with  
                                                                                 MadgeTech Fixture 4020 
                                                                                 Direct comparison using  
          Pneumatic Pressure     (1.5 to 72.5) psia        0.063 psi                Mensor CPC6000  
                                                                               with MadgeTech Fixture 4010 
                                                                              Direct comparison using Mensor 
                                   (1 to 20) psia          0.077 psi            CPC6000 with MadgeTech  
                                                                                      Fixture 4034 
       Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and 
       reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a 
       coverage factor of 2 (k=2), corresponding to a confidence  level of approximately 95%. 
       Notes: 
       1.  This scope is formatted as part of a single document including Certificate  of Accreditation No. AC-2481. 
                                           
       Version 011  Issued: April 07, 2022         www.anab.org 
                                                                                                           
                                                     Page 2 of 2 
Kata-kata yang terdapat di dalam file ini mungkin membantu anda melihat apakah file ini sesuai dengan yang dicari :

...Certificate of accreditation the ansi national board hereby attests that madgetech inc warner road nh fulfills requirements iso iec in field calibration this is valid only when accompanied by a current scope document can be verified at www anab org r douglas leonard jr vp pilr sbu expiry date june number ac laboratory accredited accordance with recognized international standard demonstrates technical competence for defined and operation quality management system refer to joint ilac iaf communique dated april dianne moulton com thermodynamic parameter equipment range expanded uncertainty reference method measurement or fluke prt c indicator deep well bath methanol distilled water silicone oil direct comparison using vaisala hmp temperature humidity measuring probe environmental chamber version issued page metrology ln dewar relative rh mass related psig psi psia mensor cpc fixture pneumatic pressure capability cmc expressed terms as multiplied coverage factor k corresponding confidence ...

no reviews yet
Please Login to review.